Skip to main content
Visitor II
March 20, 2024
Solved

Errors in figure

  • March 20, 2024
  • 1 reply
  • 1279 views

In RM0351 Reference manual Figure 420. USART block diagram, the positions of shift registers and data registers (of both Transmit and Receive) are wrong; their positions should be swapped.

errors_in_figure.png

    This topic has been closed for replies.
    Best answer by STTwo-32

    Hello @embed_elephant and welcome to the ST Community :smiling_face_with_smiling_eyes:.

    I confirme the issue on the diagram. I've escalated to the concerned team for correction (Under internal ticket number 178365).

    Thank you for your contribution.

     

    Best Regards.

    STTwo-32 

     

    1 reply

    STTwo-32Answer
    Technical Moderator
    March 20, 2024

    Hello @embed_elephant and welcome to the ST Community :smiling_face_with_smiling_eyes:.

    I confirme the issue on the diagram. I've escalated to the concerned team for correction (Under internal ticket number 178365).

    Thank you for your contribution.

     

    Best Regards.

    STTwo-32 

     

    Super User
    March 20, 2024

    Looks like the same mistake is repeated in many RMs; eg,

    AndrewNeil_0-1710960614595.png

     

    AndrewNeil_1-1710960669055.png

     

     

    Technical Moderator
    March 20, 2024

    Hello @Andrew Neil 

    We will check other RMs too. And we will be grateful for all your contributions.

    Best Regards.

    STTwo-32