So, which is correct and which is wrong?

0690X00000DBuRlQAL.png

The same is in RM313 for 'F37x.

Would those who wrote/modified AN4232 pay more attention to checking the facts through actually writing test cases, rather than applying the "modern feel and look", this must have caught their attention.

AN4232 should also mention the dramatic increase in power consumption of the COMP modules in 'G4, compared to 'F3.

@Vincent Onde​ - a prime example of why it's in ST's interest of write dozens of appnotes per module, together with concise software examples; instead of just copy/pasting from RM and rephrasing.

JW

    This topic has been closed for replies.
    Best answer by Imen GH

    Hello Jan,

    I raised the problem internally for correction.

    Best Regards,

    Imen

    6 replies

    ST Employee
    February 20, 2020

    ​Hello Jan,

    Thank you for your remark.

    I will check it and get back to you

    Imen GHAnswer
    ST Employee
    February 24, 2020

    Hello Jan,

    I raised the problem internally for correction.

    Best Regards,

    Imen

    Super User
    February 24, 2020

    Thanks, Imen!

    Jan

    @Imen GH​ 

    Super User
    May 24, 2024

    Oh dear.

    waclawekjan_0-1716540673850.png

    @Imen.D, can please this be fixed?

    Thanks,

    JW

    Technical Moderator
    May 24, 2024

    Hi @waclawek.jan,

    Thank you for pointing out this missing.

    I will push to correct this in the next release.