Skip to main content
Visitor II
September 5, 2024
Solved

stm32h7 adc trigger on hrtim

  • September 5, 2024
  • 1 reply
  • 1331 views

I am triggering adc every 100us in dma and getting data in adc callback. I am triggering adc with hrtim compare 3.

 

//hrtim cmp3 event call back

{

//reset a pin.

}

 

//adc conversion call back

{

//set a pin

}

 

for some reason the reset pin is working every cycle but set pin skips its cycle.
It means adc call back not working every cycle?
What can cause this kind of behavior?

    This topic has been closed for replies.
    Best answer by Zain

    I was using adc dma fifo, i was playing around and forgot to turn it off and that was causing the issue.

    1 reply

    Technical Moderator
    September 5, 2024

    Hello,

    To me, it could be either the NVIC priority Level or the timing 100us which is very relatively high to let ADC interrupt handler to be executed.

    1. Test 1: Decrease the timing and test.
    2. Test 2: Modify the priorities to let ADC having a priority > HRTIM NVIC prio.
    ZainAuthor
    Visitor II
    September 5, 2024

    Should i priorities adc interrupt as high?

    Technical Moderator
    September 5, 2024

    This just for test to understand the behavior.

    But you need to do one test (1 or 2) at a time.