Hi,

in ds for STM32H747xI/G  , DS12930 Rev 2 , for Temp.sensor CAL2 : 130° (Parameter) is written here:

 

AScha3_0-1721813254582.png

BUT  max. temp for chip is 125° :

AScha3_1-1721813336011.png

So i assume, this is misspelled  , because in all other : (H743, H750, H7A3 ..) 110° + 30° are given.

NOT 130° .

 

 

 

    This topic has been closed for replies.
    Best answer by STTwo-32


    Hello @AScha.3 

    I can confirm that the TS_CAL2 value has been taken for 130° on the STM32H747xI/G. 

    Best Regards.

    STTwo-32

    1 reply

    STTwo-32Answer
    Technical Moderator
    July 24, 2024


    Hello @AScha.3 

    I can confirm that the TS_CAL2 value has been taken for 130° on the STM32H747xI/G. 

    Best Regards.