Skip to main content
ajavadi679
Associate
March 3, 2016
Question

Reliability

  • March 3, 2016
  • 2 replies
  • 762 views
Posted on March 03, 2016 at 20:09

Hi, How can I get TSC101 current sensor failure rate or FIT?

This topic has been closed for replies.

2 replies

Nickname14663_O
Associate
March 4, 2016
Posted on March 04, 2016 at 16:45

Hi,

The standard conditions are:

Confidence Level (CL) = 60 %,

Activation Energy (Ea)=0.7eV (useful life)

With junction temperature (Tj)=85°C [FIT (field)],

For TSC101, FIT(field)=1

Regards,

Sylvain

ajavadi679
Associate
March 5, 2016
Posted on March 05, 2016 at 09:12

Hi Sylvain, thank you very much for your reply.