Hello,
can we connect the exposed pad of the TSB582IDT to GND in the PCB layout?
There is nothing mentioned in the datasheet regarding the exposed pad.

This topic has been closed for replies.
Best answer by Peter BENSCH

Welcome @p.stein, to the community!

below table 1 of the data sheet there is a footnote that answers your question:

Exposed pad can be left floating or connected to VCC-.

Please note that we are talking about VCC- here. Only if VCC- is identical to GND, i.e. in single supply mode, the exposed pad may be connected to GND.

Does that answer your question?

Regards
/Peter

2 replies

Peter BENSCH
Peter BENSCHBest answer
Technical Moderator
October 4, 2023

Welcome @p.stein, to the community!

below table 1 of the data sheet there is a footnote that answers your question:

Exposed pad can be left floating or connected to VCC-.

Please note that we are talking about VCC- here. Only if VCC- is identical to GND, i.e. in single supply mode, the exposed pad may be connected to GND.

Does that answer your question?

Regards
/Peter

p.steinAuthor
Associate
October 4, 2023

Thank you. I had an old version of the datasheet where the footnote was not available. We use it in single supply mode, so VCC- is connected to GND.
Yes, that answers my question. Thank you!