Liv4F module. 

 

Operating voltage range in the data sheet stated 3v-3.3v

In the Manual 1.8v-3.3v  what is true? 

 

Can you fix the documents??? 

3 replies

STOne-32
Technical Moderator
March 17, 2024

Hi @EGola.1 ,

 

Thank you for the valuable remark :

https://www.st.com/resource/en/user_manual/um3004-teseoliv4f-and-teseoliv4fm-hardware-documentation-stmicroelectronics.pdf

on our TESEO LIV4F module . 

have a great Sunday 

STOne-32

EGola.1
EGola.1Author
Associate
March 17, 2024

So, 1-8v-3.3v? 

 

Correct? 

Technical Moderator
April 4, 2024

Hi,

LIV4F can operate only at 3.3V. 

We are fixing the documentation and releasing it this quarter.

Thanks for your patience.

​In order to give better visibility on the answered topics, please click on 'Accept as Solution' on the reply which solved your issue or answered your question.
Associate II
March 3, 2026

so now we have also conflicting statements from ST employees here: STOne-32 points to UM3004 (stating 1.8V to 3.3V, can be left floating) and GalaxyQuest writes "only 3.3V" which is not even the spec from the data sheet (3V too 3.63V).

Is there any chance of a final statement? And fixed documentation?

Technical Moderator
March 3, 2026

Hi,

For operating conditions like voltage, the datasheet takes precedence, therefore 3V - 3.63V. LIV4F cannot operate down to 1.8V. The hardware manual, UM3004 is mainly for pin guidelines.

Hope this helps.

 

 

​In order to give better visibility on the answered topics, please click on 'Accept as Solution' on the reply which solved your issue or answered your question.
STOne-32
Technical Moderator
March 3, 2026

Thank you @GalaxyQuest  confirming the statement . Much appreciated 

Dear @bofh ,

Hope now it is more clear .

have a great day

STOne-32