Skip to main content
RRama.1
Visitor II
January 11, 2020
Question

For VL53L1X, we have planned to use multiple sensors in a single bus. For that we have changed the address of the sensor and worked. But for every power cycle the sensor resets to it factory address (0x29). How can we change the address

  • January 11, 2020
  • 1 reply
  • 632 views

..

This topic has been closed for replies.

1 reply

John E KVAM
ST Employee
January 13, 2020

Unfortunately, you need to go through the address change methodology at every reboot.

Put all sensors in reset.

Bring one out and change it's address.

Then bring the next out of reset then change it's address to something else.

Repeat as often as required.

Unfortunately, there is no way to change the address permanently.

  • john