I use sensor VL53L1CBV0FY/1. It works, distance is measured. I began to make calibrations and problem occured. After calling VL53L1_PerformRefSpadManagement the error -13 (VL53L1_ERROR_CONTROL_INTERFACE) is appeared.

  • March 9, 2022
  • 1 reply
  • 846 views

Inside this function I determined that the error is in inner function VL53L1_run_device_test. I can not find information about it. The PCB is wired correctly. There are interface pull-ups. Thanks.

This topic has been closed for replies.

1 reply

John E KVAM
ST Employee
March 18, 2022

This is a really odd one. A long time ago on the L0 we used to have the odd issue were the pre-programed RefSpad on a sensor was not close enough, and folks got this error. Try programming the RefSpad to 3 PRIOR to running the calibration. Does that pass?