Solved
Hi, I need MTBF/ Failure Rate information of M24C02-RMN6TP, can you provide those details for different temperature values 40 degC,60 degC,25 degC. Regards, Srinivas
..
..
Hello,
Here are the FITs at 25°C & 55°C:
25°C:
0.1 @60% confidence level
0.4 @90% confidence level
55°C:
1.8 @60% confidence level
4.5 @90% confidence level
BR
Pierre