Skip to main content
Associate
May 27, 2024
Solved

Inquiry Regarding L9961 Datasheet

  • May 27, 2024
  • 1 reply
  • 638 views

Hello,

I checked the L9961 datasheet for information on the cell voltage protection function, but couldn't find the operating voltage.

 

Other products usually provide Over Voltage Protection (OVP) for cells, but in the case of L9961, only the cell measurement range is mentioned.

 

Could you clarify if voltage limitation needs to be set solely through I2C communication between the BMS IC and MCU chips?

Best answer by GS98

Hello,

There is no default value for OV protection. This should be configured via I2C as described in section 3.4.1 of the datasheet and in the register map attached to the datasheet.

Best Regards

1 reply

GS98Best answer
ST Employee
June 17, 2024

Hello,

There is no default value for OV protection. This should be configured via I2C as described in section 3.4.1 of the datasheet and in the register map attached to the datasheet.

Best Regards