Skip to main content
Associate
October 17, 2023
Solved

Operating temperature range of IC "STW4N150"

  • October 17, 2023
  • 2 replies
  • 1409 views

Can i know the minimum Operating temperature range of this IC "STW4N150"  

This topic has been closed for replies.
Best answer by Peter BENSCH

Please note that the storage temperature must not be confused with the operating temperature and only refers to the storage of the device.
There is nothing to prevent operation at -30°C if the applicable parameters of the data sheet are observed.

2 replies

Peter BENSCH
Technical Moderator
October 17, 2023

Welcome @Pradeep2014, to the community!

you can use the STW4N150 down to -40°C, the data sheet also shows some graphs for -50°C.

Hope that helps?

Regards
/Peter

Associate
October 17, 2023

Thanks for the reply,

But the datasheet says that it has a operating temperature of max +150 and storage temperature has -55 to 150.

Can we operate in negative temperature "-30"?

Peter BENSCH
Peter BENSCHBest answer
Technical Moderator
October 18, 2023

Please note that the storage temperature must not be confused with the operating temperature and only refers to the storage of the device.
There is nothing to prevent operation at -30°C if the applicable parameters of the data sheet are observed.