Hello,

I am interesting in STLQ020PUR WITHOUT the output discharge function (presented as an option) : there is no information in the datasheet to recognize if this option is present or not versus the device reference STLQ020PUR : how to be sure that the provided device has no discharge function ?

Thanks

    This topic has been closed for replies.
    Best answer by Peter BENSCH
    The STLQ020PUR (adjustable version) does not contain the discharge function. You can also find the footnote 2 in the data sheet, table 5, stating Rlow is (available) "on specific version only". In those specific versions (not released to the market yet) Rlow would be equivalent to the on-resistance of that switching FET marked with an asterisk visible in fig. 2.
    Does it answer your question?
    Regards
    /Peter

    3 replies

    Peter BENSCH
    Peter BENSCHBest answer
    Technical Moderator
    July 4, 2022
    The STLQ020PUR (adjustable version) does not contain the discharge function. You can also find the footnote 2 in the data sheet, table 5, stating Rlow is (available) "on specific version only". In those specific versions (not released to the market yet) Rlow would be equivalent to the on-resistance of that switching FET marked with an asterisk visible in fig. 2.
    Does it answer your question?
    Regards
    /Peter
    LGARC.1
    LGARC.1Author
    Associate
    July 4, 2022

    Perfectly !

    Thanks

    Ludo

    Peter BENSCH
    Technical Moderator
    July 11, 2022

    Great!

    If the problem is resolved, please mark this topic as answered by selecting Select as best. This will help other users find that answer faster.