Skip to main content
JOlso.1
Associate
July 29, 2022
Solved

SVD errors on STM32H725, mislabeled CCR6 register

  • July 29, 2022
  • 2 replies
  • 708 views

SVD version 1.2, vs RM0468 Rev 3

TIM1 CCR6 register is mislabeled as CRR6 in the SVD file

This topic has been closed for replies.
Best answer by KDJEM.1

Hello @JOlso.1 ;

 

The svd issue is fixed in STM32H725/735 - STMicroelectronics 2.8 version.

 

Thank you.

Kaouthar

2 replies

KDJEM.1
Technical Moderator
August 1, 2022

Hi @JOlso.1​ ,

I confirm the issue: TIM1_CCR6 register is wrongly mislabeled in the SVD file.

I reported this issue internally.

Internal ticket number: 132570 (This is an internal tracking number and is not accessible or usable by customers).

Kaouthar

To give better visibility on the answered topics, please click on Accept as Solution on the reply which solved your issue or answered your question.
KDJEM.1
KDJEM.1Best answer
Technical Moderator
August 20, 2025

Hello @JOlso.1 ;

 

The svd issue is fixed in STM32H725/735 - STMicroelectronics 2.8 version.

 

Thank you.

Kaouthar

To give better visibility on the answered topics, please click on Accept as Solution on the reply which solved your issue or answered your question.