Skip to main content
Associate
April 9, 2026
Solved

CubeMX Bug Project Manager

  • April 9, 2026
  • 1 reply
  • 201 views

CubeMX Project Manager has a bug, where when I accidentally cleared the "Project Location" field and moved the cursor away CubeMX complains that project location cannot have special characters and cannot be empty. But this popup does not go away and gives you no chance to correct your mistake. Screenshot attached. 

Host OS: Ubuntu 24.04.4 

CubeMX version: 6.15.0

 

 

Edit: Turns out there was a new version of CubeMX (6.17.0) where this problem disappears. You click 4-5 times on OK and the dialog disappears. Should I delete the question in this case?

Best answer by Mahmoud Ben Romdhane

Hello  @shrinivas96 

Let me thank you for posting.

I tested with STM32CubeMX 6.17, and the behavior described is not reproduced by my side.

When I click on OK [ 2 clicks], the pop-up window disappears.

Thanks.

Mahmoud

1 reply

Technical Moderator
April 9, 2026

Hello  @shrinivas96 

Let me thank you for posting.

I tested with STM32CubeMX 6.17, and the behavior described is not reproduced by my side.

When I click on OK [ 2 clicks], the pop-up window disappears.

Thanks.

Mahmoud

To give better visibility on the answered topics, please click on Accept as Solution on the reply which solved your issue or answered your question.