Skip to main content
MMust.5
Senior
April 17, 2023
Solved

Where can I measure 25 megahertz intended for HSE?

  • April 17, 2023
  • 1 reply
  • 870 views

STM32F407 Discovery

en.MB997-F407VGT6-C01_Schematic.pdf


_legacyfs_online_stmicro_images_0693W00000biD0jQAE.pngHSE quartz 8 megahertz.

How are 4-26 MHz generated for HSE?

With an oscilloscope, I see only 8 megahertz on X2 quartz.

Where are those 25 megahertz that are listed as input for HSE?

In the documentation I read this:

This frequency cannot be changed, it is fixed at 8 MHz and connected to PH0-OSC_IN of the STM32F407VG.

But in Cube Mx this frequency can be changed from 4 to 26 megahertz.

This topic has been closed for replies.
Best answer by AScha.3

>Where are those 25 megahertz that are listed as input for HSE?

on a board with 25MHz crystal (i have one of these here)

> in Cube Mx this frequency can be changed from 4 to 26 megahertz

how should Cube know, what crystal you decide to use ???

>it is fixed at 8 MHz and connected to PH0-OSC_IN

exactly. until you solder another crystal there in. then set this new frequency in Cube!

1 reply

AScha.3
AScha.3Best answer
Super User
April 17, 2023

>Where are those 25 megahertz that are listed as input for HSE?

on a board with 25MHz crystal (i have one of these here)

> in Cube Mx this frequency can be changed from 4 to 26 megahertz

how should Cube know, what crystal you decide to use ???

>it is fixed at 8 MHz and connected to PH0-OSC_IN

exactly. until you solder another crystal there in. then set this new frequency in Cube!

"If you feel a post has answered your question, please click ""Accept as Solution""."